Overview of alarms 06/2009
NCK alarms
2-98
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Index == 6: Program SIRELAY command in synchronized action
Index == 7: Program GOTOF/GOTOB/GOTO command with block number or label
Index == 8: Load COA application "cutting generator"
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14092 [Channel %1: ] Block %2 axis %3 is wrong axis type
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions: One of the following programming errors has occurred:
1. The keyword WAITP(x) "Wait with block change until the specified positioning axis has reached its
end point" has been used for an axis that is not a positioning axis.
2. G74 "Reference point approach from the program" has been programmed for a spindle. (Only axis
addresses are permitted).
3. The keyword POS/POSA has been used for a spindle. (The keywords SPOS and SPOSA must be
programmed for spindle positioning).
4. If the alarm occurs with the "Rigid tapping" function (G331), the following causes are conceivable:
- The master spindle is not in position-controlled mode.
- Incorrect master spindle
- Master spindle without encoder
5. An axis name was programmed which no longer exists (e.g. when using axial variables as an
index). Or NO_AXIS has been programmed as an index.
6. If 14092 is output as a note with alarm 20140 Motion-synchronous action: traversing of command
axis, the following causes are possible:
- The axis is currently being traversed by the NC program already.
- An overlaid movement is active for the axis.
- The axis is active as following axis of a coupling.
- An interpolation compensation such as a temperature compensation is active for the axis.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: - Correct the part program according to which of the above errors is involved.
- Program SPOS.
- Set the correct master spindle with SETMS.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14095 [Channel %1: ] Block %2 radius for circle programming too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The radius entered for radius programming is too small, i.e. the programmed radius is smaller than
half of the distance between start and end point.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14096 [Channel %1: ] Block %2 illegal type conversion
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: During the program run, a variable value assignment or an arithmetic operation has caused data to
be processed in such a way that they have to be converted to another type. This would lead to the
value range being exceeded.
Value ranges of the various variable types:
- REAL: Property: Fractional number with dec. pt., value range: +/-(2-1022-2+1023)
- INT: Property: Integers with signs, value range: +/-(231-1)
- BOOL: Property: Truth value TRUE, FALSE, value range: 0,1
- CHAR: Property: 1 ASCII character, value range: 0-255
- STRING: Property: Character string (max. 100 values), value range: 0-255