List of action numbers 06/2009
3-314
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 127, SIMULATIONBLOCKSEARCHRUN
No. 128
No. 129
No. 130
No. 131
No. 132
Explanation Simulation block search should be initiated, i.e., the calculation results are only dis-
played on the HMI and there is NO traversing even after the block search.
Cause 1. The channel is in not in RESET
Remedy − Press Reset
Explanation Refusal to execute program range
Cause 1. The channel is in not in RESET
2. The channel is in not in Automatic
Remedy − Press Reset
− Switch to Automatic
Explanation Refusal to select PI service syntax check "_N_CHKSEL"
Cause The channel is in not in RESET
Remedy Press Reset
Explanation Refusal to start PI service syntax check "_N_CHKRUN"
Cause The channel is in not in RESET
Remedy Press Reset
Explanation Refusal to start PI service syntax check "_N_CHKABO"
Cause -
Remedy -
Explanation Refusal of PI service _N_NCKMOD (BIT 1)
Cause -
Remedy -