Overview of alarms 06/2009
NCK alarms
2-26
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
4220 [Channel %1: ] Spindle %2 declared repeatedly
Parameters: %1 = Channel number
%2 = Axis name, spindle number
Definitions: The spindle number exists more than once in the channel.
Reaction: NC not ready.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
The spindle number is stored in the axis-specific MD35000 $MA_SPIND_ASSIGN_TO_MACHAX.
The channel to which this machine axis/spindle is assigned is listed in the machine axis index. (The
machine axis number is given in the channel-specific MD20070 $MC_AXCONF_MACHAX_USED).
Program Con-
tinuation:
Switch control OFF - ON.
4225 [Channel %1: ] Axis %2 declaration as rotary axis missing
Parameters: %1 = Channel number
%2 = Axis name, axis number
Definitions: The modulo functionality requires a rotary axis (positions in [deg]).
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department.
Set MD30300 $MA_IS_ROT_AX.
Program Con-
tinuation:
Switch control OFF - ON.
4230 [Channel %1: ] Data alteration from external not possible in current
channel state
Parameters: %1 = Channel number
Definitions: It is not allowed to enter this data while the part program is being executed (e.g. setting data for work-
ing area limitation or for dry run feedrate).
Reaction: Alarm display.
Remedy: The data to be entered must be altered before starting the part program.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
4240 Runtime overflow for IPO cycle or position controller cycle, IP %1
Parameters: %1 = Program location
Definitions: The settings for the interpolation and position control cycle were modified before the last power-up
such that too little computing time is now available for the requisite cyclic task.
The alarm occurs immediately after power-up if too little runtime is available even when the axes are
stationary and the NC program has not started. However, task overflow can occur only when compu-
tation-intensive NC functions are called during program execution.
Reaction: NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Alarm reaction delay is cancelled.
Remedy: Please inform the authorized personnel/service department.
Commentaires sur ces manuels