
Cycle alarms
06/2009 Overview of alarms
2-215
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61211 [Channel %1: ] Block %2: Absolute reference missing
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An incremental indication was made, but the absolute reference is unknown.
Alarm triggered by following cycles: E_MI_CON, E_MI_PL, E_PI_CIR, E_PI_REC, E_PO_CIR,
E_PO_REC, E_PS_CIR, E_PS_HIN, E_PS_MRX, E_PS_POL, E_PS_SEQ, E_PS_XYA, E_SL_CIR,
E_SL_LON, F_PS_CIR, F_PS_MRX, F_PS_SEQ
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program an absolute position prior to using incremental indications.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61212 [Channel %1: ] Block %2: Wrong tool type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The tool type is not suitable for machining.
Alarm triggered by following cycles: CYCLE92, CYCLE951, E_DR, E_DR_O1, E_DR_PEC,
E_DR_SIN, E_MI_TXT, F_DR, F_DR_PEC, F_DR_SIN, F_DRILL, F_DRILLC, F_DRILLD,
F_DRM_DR, F_DRM_PE, F_DRM_SI, F_GROOV, F_MI_TXT, F_MT_LEN, F_PARTOF, F_ROU_Z,
F_ROUGH, F_SP_EF, F_TAP, F_TR_CON, F_UCUT_T
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Select a new tool type.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61213 [Channel %1: ] Block %2: Circle radius too small
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed circle radius is too small.
Alarm triggered by following cycles: CYCLE77, E_CR_HEL, E_PI_CIR, E_PO_CIR, E_PO_REC,
F_PI_CIR, F_PO_CIR, F_PO_REC
Remedy: Correct the circle radius, center point or end point.
61214 [Channel %1: ] Block %2: No pitch programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: No thread/helical pitch has been entered.
Alarm triggered by following cycles: E_CR_HEL, E_PO_CIR, E_PO_REC, F_PO_CIR, F_PO_REC.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program a pitch.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61215 [Channel %1: ] Block %2: Unfinished dimension incorrectly programmed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Check the blank spigot dimensions. The blank spigot must be larger than the production part spigot.
Alarm triggered by following cycles: CYCLE76, CYCLE77, E_PI_CIR, E_PI_REC, E_PO_CIR,
E_PO_REC, F_PI_CIR, F_PI_REC, F_PO_CIR, F_PO_REC
Remedy: Check parameters _AP1 and _AP2.
Commentaires sur ces manuels