PROFIBUS alarms
06/2009 Overview of alarms
2-287
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
380076 PROFIBUS/PROFINET: No DO1 message frame: Bus %2 slave/device %1
Parameters: %1 = Slave/device address
%2 = Number of the affected bus
Definitions: Note for the system startup engineer: A PROFIBUS slave/PROFINET device used as an NCK drive
does not have a valid DO1 message frame assignment (see MD13120
$MN_CONTROL_UNIT_LOGIC_ADDRESS with the STEP 7 configuration).
This alarm is indicating, among other things, that the alarm time-of-day synchronization is not working
between the controller and this slave/device.
Reaction: Alarm display.
Remedy: Enter a valid value in MD13120 $MN_CONTROL_UNIT_LOGIC_ADDRESS.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
380500 PROFIBUS/PROFINET: Fault on drive %1, code %2, value %3, time %4
Parameters: %1 = Axis
%2 = Fault code of drive (P947(/945)/P824)
%3 = Fault value of drive ((P949/P826)
%4 = Fault time of drive (P948/P825)
Definitions: Contents of fault memory of assigned drive.
Reaction: Alarm display.
Remedy: See drive documentation for fault codes/fault values.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
380501 PROFIBUS/PROFINET: Fault on bus, slave/device, DO ID %1, code %2,
value %3, time %4
Parameters: %1 = 8 bit bus number, 8 bit slave/device number, 16 bit DO ID
%2 = Fault code of drive (P947)
%3 = Fault value of the drive (P949)
%4 = Fault time of the drive (P948)
Definitions: Contents of the fault memory of the assigned slave/device.
Reaction: Alarm display.
Remedy: See drive documentation for fault codes/fault values.
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
380502 PROFIBUS/PROFINET: Bus %1, slave/device %2 configuration changed
Parameters: %1 = Bus number
%2 = Slave/device address
Definitions: The bus configuration has changed.
Causes:
- Initial start-up
- New slave/device recognized on the bus
Reaction: Interface signals are set.
Alarm display.
Remedy: In order to operate the bus with the new configuration, an additional restart will be required.
Program Con-
tinuation:
Switch control OFF - ON.
380503 PROFIBUS/PROFINET: Bus %1 configuration changed
Parameters: %1 = Bus number
Definitions: A new SDB with a modified configuration has been provided.
The new settings will be activated only at the next bus power up.
Reaction: Interface signals are set.
Alarm display.
Remedy: In order to operate the bus with the new configuration, an additional restart will be required.
Program Con-
tinuation:
Switch control OFF - ON.