Overview of alarms 06/2009
NCK alarms
2-154
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: Please inform the authorized personnel/service department. Modify program or set MD18600
$MN_MM_FRAME_FINE_TRANS to 1.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
18310 [Channel %1: ] Block %2 frame: illegal rotation
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Rotations are not possible with NCU global frames.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18311 [Channel %1: ] Block %2 frame: illegal instruction
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: An attempt was made to read or write a frame which does not exist.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18313 [Channel %1: ] Block %2 frame: illegal switchover of geometry axes
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: It is not allowed to change the geometry axis assignment because the current frame contains rota-
tions.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Change NC program or set other mode with MD10602 $MN_FRAME_GEOAX_CHANGE_MODE.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
18314 [Channel %1: ] Block %2 frame: type conflict
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: It is not possible to chain global frames and channel-specific frames. The alarm occurs if a global
frame is programmed with a channel axis name and no machine axis on this NCU is assigned to the
channel axis. Channel-specific frames cannot be programmed with machine axis names if there is no
corresponding channel axis on this NCU.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program