62306 [Channel %1: ] Block %2: Permissible measuring difference exceeded
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE971, CYCLE972, CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE982, CYCLE994
Remedy: The difference between actual and setpoint value is larger than tolerance parameter _TDIF, tool data
are not corrected.
62307 [Channel %1: ] Block %2: Maximum number of characters per line
exceeded.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105
Insufficient number of characters per line.
Remedy: Increase the value in _PROTFORM[1]
62308 [Channel %1: ] Block %2: Variable column width not possible
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
Unable to generate variable column widths, as no header available.
A fixed column width of 12 characters is used.
Reaction: Alarm display.
Remedy: Complete the header in _PROTVAL[0].
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62309 [Channel %1: ] Block %2: Insufficient column width
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE105.
The value to be logged is larger than the column width.
Reaction: Alarm display.
Remedy: Adjust _PROTFORM[5] or change the header at variable column width.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
62310 [Channel %1: ] Block %2: The max. number of characters per line is
limited to 200 characters per line
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: Alarm triggered by following cycles: CYCLE105.
The maximum number of characters per line has been limited to 200 characters per line.
Remedy: --
62311 [Channel %1: ] Block %2: The maximum number of characters per line
_PROTFORM[1] is adjusted.
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggered by the following cycles: CYCLE105
Max. number of characters per line _PROTFORM[1] has been adjusted.
Reaction: Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.