Overview of alarms 06/2009
NCK alarms
2-92
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Alarm display.
Remedy: Ensure that the subroutine (alarm parameter %3)
- is available in the parts program memory
- has been released and is not being edited
- is available in the search path if not being called via an absolute path name.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14012 [Channel %1: ] Block %2 maximum subroutine level exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The maximum nesting depth of 8 program levels has been exceeded.
Subroutines can be called from the main program, and these in turn may have a nesting depth of 7.
In interrupt routines the maximum number of levels is 4!
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify the machining program so that the nesting depth is reduced, e.g. using the editor copy a sub-
routine of the next nesting level into the calling program and remove the call for this subroutine. This
reduces the nesting depth by one program level.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
14013 [Channel %1: ] Block %2 number of subroutine passes invalid
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In a subroutine call the programmed number of passes P is zero or negative.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Program number of passes between 1 and 9 999.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14014 [Channel %1: ] Selected program %3 not available or will be edited
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions: The selected parts program is not in the NCK memory or the access authorization for the program
selection is from a higher level than the current control status.
During creation, this program received the protection level of the NC control which was active at the
time.
In SW 5 or higher a program edited on HMI can no longer be started with NC Start.
The alarm will also be issued, if a file other than the specified definition file has been selected for the
GUD or macro definition.
Reaction: Alarm display.
Remedy: Reload the program in the NCK memory or check and correct the name of the directory (workpiece
overview) and the program (program overview) and reselect.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
14015 [Channel %1: ] Block %2 program %3 is not enabled
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions: The execution right currently set in the control (e.g. key switch position 0) is inadequate to execute
part program %3.
Reaction: Correction block is reorganized.
Interface signals are set.
Vue de la page 91