
NCK alarms
06/2009 Overview of alarms
2-123
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
- Definition of LUDs in incorrect subroutine level
- Transferred circle coordinates
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15810 [Channel %1: ] Block %2 wrong array dimension for
CONTPRON/CONTDCON
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of columns for the array created for CONTPRON/CONTDCON does not conform to the
current programming guide.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15900 [Channel %1: ] Block %2 touch probe not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Measure with deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAS (measure with
deletion of distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAS=2 G01 X100 Y200 Z300 F1000
Probe 2 with deletion of distance-to-go
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Include a probe number within the limits given above in the keyword MEAS=... This must correspond
to the hardware connection of the probe.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
15910 [Channel %1: ] Block %2 touch probe not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Measure without deletion of distance-to-go
In the part program, an illegal probe has been programmed with the command MEAW (measure with-
out distance-to-go). The probe numbers
0 ... no probe
1 ... probe 1
2 ... probe 2
are allowed, whether the probe is actually connected or not.
Example:
N10 MEAW=2 G01 X100 Y200 Z300 F1000
Probe 2 without deletion of distance-to-go
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Commentaires sur ces manuels