Overview of alarms 06/2009
NCK alarms
2-148
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17181 [Channel %1: ] Block %2 T no.= %3, D no.= %4 not existing
Parameters: %1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions: A programmed D number was not recognized by the NC. By default, the D number refers to the spec-
ified T number. If the flat D number function is active, T= 1 is output.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: If the program is incorrect, remedy the error with a correction block and continue the program.
If the data block is missing, download a data block for the specified T/D values onto the NCK (via HMI
with overstore) and continue the program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17183 [Channel %1: ] Block %2 H number already available in T no.= %3, D no.=
%4
Parameters: %1 = Channel number
%2 = Block number, label
%3 = T number
%4 = D number
Definitions: Each H number (except for H=0) must be assigned in a TO unit only once. The indicated edge already
has the H number. If the H number shall be assigned more than once, MD10890
$MN_EXTERN_TOOLPROG_MODE, bit 3 must be set = 1.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: - Change program:
- Select different H number
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17188 [Channel %1: ] D number %2 defined in tool T no. %3 and %4
Parameters: %1 = Channel number
%2 = Offset number D
%3 = T number of first tool
%4 = T number of second tool
Definitions: The specified D number %2 in the TO unit of channel %1 is not unique. The specified T numbers %3
and %4 each have an offset with number %2. If tool management is active: The specified T numbers
belong to tool groups with different names.
Reaction: Interface signals are set.
Alarm display.
Remedy: 1. Ensure that the D numbers within the TO unit are unique.
2. If unique numbering is not necessary for subsequent operations, do not use the command.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
17190 [Channel %1: ] Block %2 illegal T number %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = T number
Definitions: In the displayed block, access is made to a tool that is not defined and therefore not available. The
tool has been named by its T number, its name or its name and duplo number.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.