Cycle alarms
06/2009 Overview of alarms
2-255
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
61613 [Channel %1: ] Block %2: Undercut position incorrectly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE94, CYCLE96.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check value in parameter _VARI.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61701 [Channel %1: ] Block %2: Error in finished part contour description
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Either none of parameters _NP1, _NP2 and _NP3 supplied or error in finished part contour program-
ming.
Alarm triggered by following cycle: CYCLE950
Remedy: - Check parameters _NP1, _NP2 and _NP3.
- Check finished-part contour programming.
61702 [Channel %1: ] Block %2: Error in blank contour description
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Either none of parameters _NP5, _NP6 and _NP7 supplied or error in blank contour programming.
The alarm is triggered by the following cycles: CYCLE950
Remedy: - Check parameters _NP5, _NP6 and _NP7.
- Check blank contour programming.
61703 [Channel %1: ] Block %2: Internal cycle error while deleting file
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE950, CYCLE73, CYCLE74, CYCLE75.
Remedy: --
61704 [Channel %1: ] Block %2: Internal cycle error while writing to file
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE950, CYCLE73, CYCLE74, CYCLE75.
Remedy: --
61705 [Channel %1: ] Block %2: Internal cycle error while reading to file
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE950, CYCLE73, CYCLE74, CYCLE75.
Remedy: --
61706 [Channel %1: ] Block %2: Internal cycle error while generating checksum
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE950, CYCLE73, CYCLE74, CYCLE75.
Remedy: --
61707 [Channel %1: ] Block %2: internal cycle error with ACTIVATE at HMI
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE950, CYCLE73, CYCLE74, CYCLE75.
Remedy: --