NCK alarms
06/2009 Overview of alarms
2-81
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Macros are loaded during POWER ON/NCK RESET or selectively via PI service _N_F_COPY (acti-
vate macro via HMI dialog). If alarm 15180 refers to a macro definition file, then MD18160
$MN_MM_NUM_USER_MACROS is set to a value that is too small.
Cycle program definitions (PROC instruction) are reloaded at each POWER ON/NCK RESET. In case
of failure check parameter %3 to find out whether the name of the cycle program has caused the error
- in this case, the value of MD18170 $MN_MM_NUM_MAX_FUNC_NAMES should be increased, or
whether the name of a cycle call parameter has caused the error - in this case, the value of MD18180
$MN_MM_NUM_MAX_FUNC_PARAM should be increased.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12470 [Channel %1: ] Block %2 G function %3 is unknown
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: With indirectly programmed G functions, an invalid or non-allowed group number has been pro-
grammed. Allowed group number = 1. and 5 max. number of G groups. In the displayed block, a non-
defined G function has been programmed. Only "real" G functions are checked, which begin with the
address G, e.g. G555. "Named" G functions such as CSPLINE, BRISK etc. are interpreted as subrou-
tine names.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Press the NC Stop key and select the function "Correction block" with the softkey PROGRAM COR-
RECT. The correction pointer positions on the incorrect block. You should decide on the basis of the
machine manufacturer's programming guide whether or not the displayed G function exists or is avail-
able, or whether a standard G function has been reconfigured (or introduced by an OEM). Remove G
function from the part program or program function call in accordance with the machine manufac-
turer's programming guide.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12475 [Channel %1: ] Block %2 invalid G function number %3 programmed
Parameters: %1 = Channel number
%2 = Block number, label
%3 = G code number
Definitions: A non-allowed G function number (parameter 3) has been programmed for a G group with indirect G
code programming. Only the G function numbers indicated in the Programming Guide "Fundamen-
tals", Section 12.3 "List of G functions/Path conditions" are allowed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
12480 [Channel %1: ] Block %2 subroutine %3 already defined
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Source string
Definitions: The name used in the PROC or EXTERN instruction has already been defined in another call descrip-
tion (e.g. for cycles).
Example:
EXTERN CYCLE85 (VAR TYP1, VAR TYP2, ...)
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.