Siemens SINUMERIK 802D sl Manuel de l'opérateur Page 204

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 340
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 203
Overview of alarms 06/2009
Cycle alarms
2-204
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61126 [Channel %1: ] Block %2: Thread length too short
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE840.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program lower spindle speed/raise reference plane.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61127 [Channel %1: ] Block %2: Wrong definition of tapping axis
transformation ratio (machine data)
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check machine data 31050 and 31060 in the appropriate gear stage of the drilling axis.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61128 [Channel %1: ] Block %2: Insertion angle = 0 for insertion with oscillation
or helix
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: SLOT1.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _STA2.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61129 [Channel %1: ] Block %2: perpendic. approach and retraction during
contour milling only allowed with G40
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycle: CYCLE72.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61130 [Channel %1: ] Block %2: positions of parallel axes cannot be
compensated. No workpiece reference agreed.
Parameters: %1 = Channel number
%2 = Block number, label
Vue de la page 203