06/2009 List of action numbers
3-303
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
No. 63, PROGMODEDRYRUNON
No. 64, PROGMODEDRYRUNOFF
No. 65, BLOCKREADINHIBIT_ON
No. 66, BLOCKREADINHIBIT_OFF
No. 67, STOPATEND_ALARM
No. 68, STOP_ALARM
Explanation Activate test run (VDI signal: Rapid traverse override)
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Wait until the preceding ASUB is complete or abort the program.
Abort program
Explanation Deactivate test run (VDI signal: Rapid traverse override)
Cause 1. Nesting depth too great
2. The active block, after which deceleration takes place, cannot be reorganized (occurs
when deceleration takes place over several blocks).
Remedy Wait until the preceding ASUB is complete or
Abort program
Explanation Activate read-in disable for main run block (VDI signal: Read-in disable).
Cause -
Remedy -
Explanation Deactivate read-in disable for main run block (VDI signal: Read-in disable).
Cause -
Remedy -
Explanation Stop at block end (alarm)
Cause -
Remedy -
Explanation Stop all axes (alarm)
Cause -
Remedy -