Overview of alarms 06/2009
NCK alarms
2-28
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Program Con-
tinuation:
Switch control OFF - ON.
4300 Declaration in MD %1 is not allowed for axis %2.
Parameters: %1 = String: MD identifier
%2 = Axis name, spindle number
Definitions: The axis cannot be operated as competing positioning axes,
for example because the axis is the slave axis within a closed gantry group or a gantry group to be
closed.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department. Reset MD30450
$MA_IS_CONCURRENT_POS_AX for the axis concerned.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4310 Declaration in MD %1 index %2 is not allowed.
Parameters: %1 = String: MD identifier
%2 = Index: MD array index
Definitions: The machine data values must be written in the array in ascending order.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Please inform the authorized personnel/service department. Correct the MD.
Program Con-
tinuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
4320 Axis %1 function %2 %3 and %4 not allowed
Parameters: %1 = String: Axis identifier
%2 = String: MD identifier
%3 = String: Bit
%4 = String: MD identifier
Definitions: The functions declared by the specified machine data cannot simultaneously be active for one axis.
Reaction: Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Deactivate one of the functions.
Program Con-
tinuation:
Switch control OFF - ON.
4340 [Channel %1: ] Block %2 invalid transformation type in transformation
no. %3
Parameters: %1 = Channel number
%2 = Block number, label
%3 = Transformation number
Definitions: An invalid, i.e. undefined, number was entered in one of the machine data TRAFO_TYPE_1 ...
TRAFO_TYPE_8. This alarm also occurs if a certain type of transformation is only impossible on the
type of control used (e.g. 5-axis transformation on a SINUMERIK 802D sl).
Reaction: Correction block is reorganized.802D sl
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy: Enter a valid transformation type.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Vue de la page 27