Overview of alarms 06/2009
NCK alarms
2-142
© Siemens AG 2009 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2009
Remedy: MD11550 $MN_STOP_MODE_MASK and language command DELAYFSTON DELAYFSTOF
Program Con-
tinuation:
Alarm display showing cause of alarm disappears. No further operator action necessary.
17000 [Channel %1: ] Block %2 maximum number of symbols exceeded
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The maximum number of symbols defined by machine data MD28020
$MC_MM_NUM_LUD_NAMES_TOTAL has been exceeded.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
- Modify machine data
- Reduce the number of symbols (variables, subroutines, parameters)
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
17001 [Channel %1: ] Block %2 no memory left for tool/magazine data
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The number of following tool/magazine data variables in the NC are given by machine data:
- Number of tools + number of grinding data blocks: MD18082 $MN_MM_NUM_TOOL
- Number of cutting edges: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
Tools, grinding data blocks, cutting edges can be used independently of the tool management.
The memory for the following data is available only if the corresponding bit has been set in MD18080
$MN_MM_TOOL_MANAGEMENT_MASK.
- Number of monitoring data blocks: MD18100 $MN_MM_NUM_CUTTING_EDGES_IN_TOA
- Number of magazines: MD18084 $MN_MM_NUM_MAGAZINE
- Number of magazine locations: MD18086 $MN_MM_NUM_MAGAZINE_LOCATION
The following variable is determined by software configuration: Number of magazine spacing data
blocks: P2 permits 32 such spacing data blocks.
Definition:
- 'Grinding data blocks': Grinding data can be defined for a tool from type 400 to 499. Such a data
block occupies as much additional memory as that provided for a cutting edge.
- 'Monitoring data blocks': Each cutting edge of a tool can be supplemented by monitoring data.
- If the alarm occurs while writing from one of the parameters $TC_MDP1/$TC_MDP2/$TC_MLSR,
check whether machine data MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC /
MD18076$MN_MM_NUM_LOCS_WITH_DISTANCE have been correctly set.
MD18077 $MN_MM_NUM_DIST_REL_PER_MAGLOC defines the number of different Index1 state-
ments that may be made for an Index2 value.
MD18076 $MN_MM_NUM_LOCS_WITH_DISTANCE defines the number of different buffer storage
locations that may be named in Index2.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Please inform the authorized personnel/service department.
- Modify machine data
- Modify NC program, i.e. reduce number of rejected variable.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
17010 [Channel %1: ] Block %2 no memory left
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: When executing/reading files from the active working memory, it was found that there is not enough
memory space (e.g. for large multidimensional arrays or when creating tool offset memory).
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.