Overview of alarms 06/2007
NCK alarms/ISO alarms
2-42
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
Remedy: The cause of this message may be that the NCK is running on hardware that is not intended for this
NCK version (i.e. it has insufficient memory).
If the application runs properly with the remaining free user memory (i.e. can be started up without any
errors), the message can simply be ignored.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
6200 Memory for CC MD full.
Definitions: The memory reserved for storage of compile cycle machine data is full.
Some of these machine data could not be created correctly.
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
If the alarm is displayed on start-up of compile cycles, this may be remedied by increasing
$MN_MM_CC_MD_MEM_SIZE.
Program Con-
tinuation:
Switch control OFF - ON.
6410 TO unit %1 tool %2 has reached its prewarning limit with D = %4
Parameters: %1 = TO unit
%2 = Tool identifier (name)
%3 = Duplo number
%4 = D number
Definitions: Tool monitoring:
This message informs that the specified D offset has reached its prewarning limit for a time- or quan-
tity-monitored tool.
If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
The actual type of tool monitoring is a tool property (see $TC TP9).
If replacement tools are not being used,
the duplo number specified has no meaning.
The alarm is triggered through the MMC or PLC (=OPI interface). The channel context is not defined.
The TO unit is specified for this reason.
Reaction: Interface signals are set.
Alarm display.
Remedy: For information only. The user must decide what to do.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
6411 Channel %1 tool %2 has reached its prewarning limit with D = %4
Parameters: %1 = TO unit
%2 = Tool identifier (name).
%3 = Duplo number
%4 = D number
Definitions: Tool monitoring:
This message informs that the specified D offset has reached its prewarning limit for a time- or quan-
tity-monitored tool.
If possible, the D number is displayed; if not, value 0 is assigned to the 4th parameter.
The actual type of tool monitoring is a tool property (see $TC TP9).
If replacement tools are not being used,
the duplo number specified has no meaning.
The alarm originates during NC program execution.
Reaction: Interface signals are set.
Alarm display.
Remedy: For information only. The user must decide what to do.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
Commentaires sur ces manuels