List of action numbers 06/2007
3-364
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 127, SIMULATIONBLOCKSEARCHRUN
No. 128
No. 129
No. 130
No. 131
No. 132
Explanation Simulation block search should be initiated, i.e., the calculation results are only dis-
played on the HMI and there is NO traversing even after the block search.
Cause 1. The channel is in not in RESET
Remedy Press Reset
Explanation Refusal to execute program range
Cause 1. The channel is in not in RESET
2. The channel is in not in Automatic
Remedy Press Reset
Switch to Automatic
Explanation Refusal to select PI service syntax check "_N_CHKSEL"
Cause The channel is in not in RESET
Remedy Press Reset
Explanation Refusal to start PI service syntax check "_N_CHKRUN"
Cause The channel is in not in RESET
Remedy Press Reset
Explanation Refusal to start PI service syntax check "_N_CHKABO"
Cause -
Remedy -
Explanation Refusal of PI service _N_NCKMOD (BIT 1)
Cause -
Remedy -