
Overview of alarms 06/2007
NCK alarms/ISO alarms
2-144
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
14752 Channel %1 block %2 DELDTG | STOPREOF conflict
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: In a block of motion synchronous actions referring to a motion block, both DELDTG (delete distance-
to-go) and STOPREOF (preprocessing stop) have been programmed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: The functions DELDTG and STOPREOF exclude each other in a block.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14753 Channel %1 block %2 motion synchronous actions with illegal
interpolation type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion synchronous
action or for the function "Several feeds".
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14754 Channel %1 block %2 motion synchronous actions and wrong feed type
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The active feed type is not allowed for the motion synchronous action or for the function "Several
feeds".
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14755 Channel %1 block %2 motion synchronous actions without traverse
motion
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The programmed motion synchronous action and the function "Several feeds" require a traversing
motion or the value of the traversing motion is 0.
This alarm is no longer used after P3.2.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.
14756 Channel %1 block %2 motion synchronous action and wrong value
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Value of the synchronous action or the function "Several feeds" is not allowed.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Modify part program. Check whether a negative value was entered for a synchronous action.
Commentaires sur ces manuels