Cycle alarms
06/2007 Overview of alarms
2-271
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
61009 Channel %1 Block %2: Active tool number = 0
Parameters:
Definitions: Source (cycle):
CYCLE71
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: No tool (T) has been programmed before the cycle call.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61010 Channel %1 Block %2: Finishing allowance too large
Parameters:
Definitions: Source (cycle):
CYCLE71
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: An active scaling factor is active which is not permissible for this cycle.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61011 Channel %1 Block %2: Scaling not permissible
Parameters:
Definitions: Source (cycle):
CYCLE72
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The finishing allowance at the base is larger than the overall depth, it must be reduced.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61012 Channel %1 Block %2: Different scaling in planes
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: Alarm triggered by following cycles: CYCLE76, CYCLE77.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: --
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program