Overview of alarms 06/2007
NCK alarms/ISO alarms
2-160
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
15700 Channel %1 block %2 illegal cycle alarm number %3
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A SETAL command with a cycle alarm number smaller than
60,000 or larger than 67,999 has been programmed.
Alarm Reactions of Siemens standard cycles:
No. 61 000 - 61 999: Interpreter stop; delete with reset
No. 62 000 - 62 999: Compensation block; delete with NC Start
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Program alarm number in the SETAL instruction in the correct range.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15800 Channel %1 block %2 wrong starting conditions for
CONTPRON/CONTDCON
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The starting conditions are faulty for the contour preparation (CYCLE 95):
G40 (deselection of the tool radius compensation) is not active
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Change part program: Deselect tool radius compensation with G40.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15810 Channel %1 block %2 wrong array dimension for
CONTPRON/CONTDCON
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The column number for a contour table has a fixed size. The current value is contained in the current
Technology Programmer's Guide.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Correct the array definition for the contour table.
The number of rows can be defined freely and corresponds to the number of contour elements (circles,
straight lines). The number of columns is fixed (see the Cycle Programming Guide).
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15900 Channel %1 block %2 touch probe not allowed
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: A non-existent touch probe for measuring with deletion of remaining distance has been selected in the
part program.
Reaction: Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy: Change part program.
Program Con-
tinuation:
Clear alarm with NC START or RESET key and continue the program.