Overview of alarms 06/2007
NCK alarms/ISO alarms
2-158
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007Edition
15350 Channel %1 block %2 search target not found
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The specified program has been searched to the end of the program without the selected search tar-
get having been found.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check the part program, change the block search (typing error in the part program) and restart the
search.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15360 Channel %1 illegal target of block search (syntax error)
Parameters: %1 = channel number
Definitions: The specified search target (block number, label or string) is not allowed in block search.
Reaction: Alarm display.
Remedy: Correct target of block search.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15370 Channel %1 target of block search not found
Parameters: %1 = channel number
Definitions: In a block search, an impermissible search target has been specified (e.g. negative block number).
Reaction: Alarm display.
Remedy: Check the specified block number, label or character string. Repeat entry with correct search target.
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
15380 Channel %1 block %2 illegal incremental programming in axis %3
Parameters: %1 = Channel number.
%2 = Block number, label.
%3 = Axis.
Definitions: A transformation change occurred after "search at block end".
The position accumulated during the search cannot be traversed incrementally.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Find search destination in which the axes are programmed using an absolute reference.
Deactivate adding of the accumulated search position with SD 42444 TARGET_BLOCK_INCR_ =
FALSE.
Use search run with calculation "at contour".
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
15400 Channel %1 block %2 selected initial init file does not exist
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The operator has selected an INI block for a read, write or execution function which:
1.Does not exist in the NC range or
2.Does not have the protection level required to perform the function
Reaction: Alarm display.
Remedy: Please inform the authorized personnel/service department.
Check whether the selected INI block is contained in the file system of the NC. The present protection
level must be selected to be at least equal to (or greater than) the protection level that has been
defined for the read, write or execution function at the time of creating the file.