Overview of alarms 06/2007
Cycle alarms
2-292
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Definitions: Only manual tools may be loaded into a swivel head in which only manual tools can be loaded.
The alarm is triggered by the following cycles: E_TD, E_TFS, F_TFS
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Load a manual tool into the swivel head or set the parameter "Tool change" in the start-up screen form
"Rotary axes" to "Automatic".
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61233 Channel %1 block %2: Thread angle wrongly defined
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: The thread angles were specified too large or too small.
Alarm triggered by following cycles: E_TR_CON, F_TR_CON
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check thread geometry.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61234 Channel %1 block %2: ShopMill subroutine %4 cannot be executed, as
not tested by ShopMill
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Subroutine name
Definitions: Before a ShopMill subroutine can be used, it has to be tested by ShopMill.
Alarm triggered by following cycle: E_HEAD.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: The subroutine has to be simulated first in ShopMill or loaded into the ShopMill operating mode
"Machine auto".
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61235 Channel %1 block %2: ShopTurn program %4 cannot be executed as not
tested by ShopTurn.
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Program name
Definitions: Before a ShopTurn program can be executed, it has to be tested by ShopTurn.
Alarm triggered by following cycle: F_HEAD
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Simulate the subroutine first in ShopTurn or load it into the ShopTurn operating mode "Machine auto".
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61236 Channel %1 block %2: ShopTurn subroutine %4 cannot be executed as
not tested by ShopTurn.
Parameters: %1 = Channel number
%2 = Block number, label
%4 = Subroutine name