Overview of alarms 06/2007
Cycle alarms
2-306
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61321 Channel %1 Block %2: Check WO memory number
Parameters: %1 = Channel number
%2 = Block number, label
Definitions: WO with the number specified in _KNUM not existing. Alarm is triggered: CYCLE974, CYCLE977,
CYCLE978, CYCLE979, CYCLE994, CYCLE998.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Check parameter _KNUM.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61337 Channel %1 Block %2: Check measuring input
Parameters: %1 = Channel number
%2 = Block number, label
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61346 Channel %1 Block %2: Distance starting point/measuring point _SETV[0]
and _SETV[1] <=0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions: The alarm is triggerd by the following cycles: CYCLE961.
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy: Parameters _SETV[0] or _SETV[1] are empty or smaller than 0.
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
61348 Channel %1 Block %2: Angle rel. to reference edge equals 0
Parameters: %1 = Channel number
%2 = Block number, label channel number
Definitions:
Reaction: Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
Commentaires sur ces manuels