06/2007 List of action numbers
3-359
" Siemens AG 2007 All Rights Reserved
SINUMERIK 802D sl, Diagnostics Manual, 06/2007 Edition
No. 98, ESR
No. 99, BLOCKSEARCHRUN_SIGNAL
No. 100, BLOCKSEARCHRUN_INTEGR
No. 101, EXT_ZERO_POINT
No. 102, SINGLEBLOCK_IPONOSBLOF
No. 103, SINGLEAX_STOPALL_MASTER
Explanation Extended stop and retract
Cause -
Remedy -
Explanation Block search (general) is currently being activated (negative acknowledgement may be
output for PI service).
Cause -
Remedy -
Explanation Integrated block search, i.e., a block search is restarted on a stopped program.
Cause -
Remedy -
Explanation External zero offset is activated via the PLC. Movement is stopped, a Reorg is per-
formed, the interpreter is switched over and then selected using REPOS and continued
automatically.
Cause 1. The channel is not in AUTO or MDI
2. The channel has been stopped and the current block cannot be reorganized.
Remedy − Select Auto or MDI
− Activate a block change until the NC block can be reorganized.
Explanation Single block type 3 is activated. With single block type 3, a stop is performed at all main
blocks. Unlike single block type 1, the part program command SBLOF is ignored.
Cause -
Remedy -
Explanation Stopping of a single axis movement (VDI signal)
Cause The axis is not controlled by the PLC. (exception old reaction with oscillation axis).
Remedy -