1 Properties / Services
B−8
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
The addressing mode can be configured for FETCH/WRITE access as the
S7 or S5 addressing mode.
− LOCK/UNLOCK with FETCH/WRITE services;
− Connection diagnostics using the user program
S IT functions
− Monitoring devices and process data (HTML process control)
− FTP functions (File Transfer Protocol) for file management and access to
data blocks in the CPU (client and server functions)
If you do not require these functions, you can disable them in the STEP 7
configuration and disable the port (properties dialog of the CP > “IP Access
Protection” tab).
− Sending E-mail via ESMTP with “SMTP-Auth” for authentication on an
E-mail server
1.3 Other services
S Media redundancy (MRP)
Within an Ethernet network with a ring topology, the CP supports the media
redundancy protocol MRP. You can assign the role of redundancy manager to
the CP.
If you are using IRT communication, no media redundancy is supported.
S Time-of-day synchronization over Industrial Ethernet using the following
configurable modes:
− SIMATIC mode
The CP receives MMS time messages and synchronizes its local time and
the time of the CPU.
(accuracy approx. +/− 1 second)
You can choose whether or not the time of day is forwarded. The forwarding
direction can also be selected (station > LAN or LAN > station).
Synchronization using the SIMATIC mode is only possible on the
PROFINET interface.
or
− NTP mode (NTP: Network Time Protocol)
The CP sends time-of-day queries at regular intervals to an NTP server and
synchronizes its local time of day and the time of the CPU (accuracy approx.
+/− 1 second).
Via the gigabit interface, synchronization is possible only with the NTP
mode.