5 Performance Data / Operation
B37
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
Table 5-9 Characteristic data for PROFINET CBA communication, Fortsetzung
Characteristic Limit valueTypical value
Access to S7extended variables
Maximum number of S7 connections for access to
variables with the PROFINET attribute
“s7extended”.
Note: The PROFINET attribute “s7extended” is
used only by OPC applications over the OPC
server; variables with this attribute can only be
used with OPC applications.
16
(not checked by iMap)
32 maximum
Note: You should also
keep in mind the
maximum number of
connections according
to Section 7.3
*) The value is not checked by iMap.
Note
For information on the data length and data type in PROFINET CBA
communication, refer to the online help on SIMATIC iMap, the “Creating
PROFINET Components” manual and the “Configuring Plants with SIMATIC iMap”
manual.
Reaction times for PROFINET CBA
The achievable reaction times for PROFINET CBA communication depend on the
following factors:
S Type of interconnection (cyclic or acyclic) and the transmission frequency or
scanning frequency
S Configuration limits on the component interface (interface DB of the PROFINET
CBA function block (FB88))