9 Further Notes on Operation
B60
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
The data in the file system of the C-PLUG (flash area) is retained, the retentive
parameters are deleted.
This has the following overall effect:
Data maintained on the S7-300
CPU.
Deleted data areas
Factory-set MAC
address
Permanent
data
C-PLUG
Retentive parameters
Flash file system
RAM area
Volatile RAM file
system (/ram)
CPU data
Configuration data
Note
Remember that the interconnection information for PROFINET CBA belongs to the
retentively stored parameters on the C-PLUG and is therefore deleted by this
action.