7 The CP as Web server
B−53
CP 343-1 Advancedfor Industrial Ethernet / Manual Part B
Release 06/2008
C79000-G8976-C202-04
The Web server function is enabled as default.
Web browser
To access the HTML pages on the CP, you require a Web browser. The following
Web browsers are suitable for communication with the CP (other browsers also
possible):
S Internet Explorer (recommended version: 6.0 or higher)
S Opera (recommended version: 9.2 or higher)
S Firefox (recommended version: 2.0 or higher)
These Web browsers support all the requirements necessary for the
implementation of the IT functions (Java reference implementation − Java
Development Kit) 1.1.x is supported) in conjunction with the CP.
You will find these Web browsers, information and add-ons on the Internet.
7.2 Web diagnostics − Language setting of the text file for
diagnostic buffer events
Diagnostic buffer events can be output in Web diagnostics. The necessary text file
is available in English on the CP when it ships.
You can change the language of the diagnostic messages by writing the text file
from your STEP 7 installation to the file system of the CP by transferring it with
FTP. As soon as a text file is transferred to the file system of the CP as described
below, the CP uses this file instead of the default text file as shipped.
S If STEP*7 is installed, you will find the text files for specific languages on your
PG/PC in:
..\Program files\Common files\Siemens\s7wmed\data
The files are stored there in the form “s7wmeldx.edb”,
(where x = {a,b,c,d,e,j}
a = German; b = English; c = French; d = Spanish; e = Italian; j = Japanese)
To transfer the file with FTP, change the name of the required file to
“s7wmeld.edb”.
S The file must be transferred by FTP in binary mode and stored in the file
system of the CP in:
/config/s7wmeld.edb (case-sensitive)
Note
You can also use the method described here to update the text file.