96 Siemens Simatic S7 Driver Online Help
[7] Enter a name for the database source file in the dialog box that appears.
[8] Select Generate Binary DB As from the File menu.
[9] Enter a name for the binary database file you want to create.
After creating a connection database, define the communication processor you want
to use and assign a connection database to it:
[1] Start the PG/PC Interface program:
[a] Select Simatic. A context menu appears.
[b] Select SIMATIC NET. A context menu appears.
[c] Select Setting the PG/PC Interface. The Set PG/PC Interface dialog box
appears.
[2] Select a communication processor from the Access Point of the Application
field and proceed to step 3.
If the communication processor you want to use is not listed, add the
communication processor names you require:
[a] Select <Add/Delete>. The Add/Delete Access Points dialog box
appears.
[b] Enter the name of the communication processor you want to use in the
New Access Point field.
[c] Enter a description for the communication processor in the Description
field and click Add.
[d] Repeat steps b and c until you have added all the communication
processor names you require.
[e] Click Close to return to the Set PG/PC Interface dialog box and select a
communication processor from the Access Point of the Application
field.
[3] Select the communication path you want to use from the Interface Parameter
Assignment Used field.