Appendix
A.1 Application Examples
Inverter with CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2011, FW 4.4, A5E02299792B AB
291
① Activate the tab "Address
configuration".
② Select line 1.
③ Open the dialog box in which you
define the Publisher and the address
area to be transferred.
① Select DX for direct data exchange
② Select the PROFIBUS address of drive 1
(publisher).
③ In the address field, select the start
address specifying the data area to be
received from drive 1. In the example, these
are the status word 1 (PZD1) and the speed
actual value with the start address 256.
Close both screen forms with OK. You have now defined the value range for slave-to-slave
communication.
In the slave-to-slave communication, drive 2 receives the sent data and writes this into the
next available words, in this case, PZD3 and PZD4.
Settings in drive 2 (subscriber)
Drive 2 is preset in such a way that it receives its setpoint from the higher-level control. In
order that drive 2 accepts the actual value sent from drive 1 as setpoint, you must set the
following:
● In drive 2 ,set the PROFIdrive telegram selection to "Free telegram configuration with
BICO" (p0922 = 999).
● In drive 2, set the source of the main setpoint to p1070 = 2050.3.
Commentaires sur ces manuels