MODEL DESIGNATION AND SPECIFICATIONS UM344-2
September 1995
(2) Not available with FM/CSA Units.
(3) Tags - The permanent transmitter nameplate can be stamped with a tagname of up to 8 characters. Optional, wired-on SS
tags are also available.
(4) Refer to SD344 for details.
8.2 ACCESSORIES
Table 8.2 lists the general accessories available for the transmitter. Accessories are ordered separately
since they are not included in a transmitter’s model number.
Table 8.3 lists the thermal sensors commonly available for the transmitter. Each sensor can be provided
as an integral or remote assembly. The integral version, shown in Figure 8-1, provides a direct connection
that becomes part of the transmitter assembly. The remote version, shown in Figure 8-2, includes a
connection head that provides a termination point for the sensor wires, allowing the sensor to be installed
separately.
TABLE 8.2 General Accessories
DESCRIPTION PART NUMBER
Transient Protection* 14999-287
General Purpose Power Supply, 24 Vdc, 2A* 15124-1
Field Mounted Power Supply, 28 Vdc, 125 mA*
(NEMA 4x, EP)
16055-299
Communication Filter Kit* 16202-3
Digital Meter Kit* 15965-808
Moore XTC Communicator (MXC) 15965-665
TABLE 8.3 Thermal Sensors
DESCRIPTION BASIC REFERENCE
NUMBER
Threaded Bar Stock Well Assembly 344T1**
Flanged Bar Stock Assembly 344T2**
Socket or Weld-In Assembly 344T3**
Flanged Pipe Well Assembly 344T5**
Industrial CERAMOCOUPLE® Assembly 344T6**
Sanitary Probe 344T7** and 344T8**
* Refer to PI34-3, XTC Transmitter Accessory Guide for additional details.