Vue de la page 40
Installation and Maintenance
5.2 Installation of the Modules
SIMATIC NET PROFIBUS Optical Link Module OLM V4.0
Operating Instructions, 01/2013, C79000-G8976-C270-03
35
Installation on a mounting plate
Unscrew the 3 screws on the right side of the OLM (the side with the type label).
Fix with this screws the mounting plate (MLFB: 6GK1503-8AA00).
Now fix the OLM at the wall or at a cubicle plate.
Make sure there is a reliable and permanent electrical connection between the mounting plate and surface,
for example by using toothed washers.
mounting plate with
OLM on the front
holes for wall (plate)
installation
Figure 5-5 Installation of a module with a mounting plate