Siemens SIMATIC NET CP 343-1 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mise en réseau Siemens SIMATIC NET CP 343-1. CP 343-1 Lean (CX10) Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 68
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
CP 343-
1 Lean
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
_
_________________
_
SIMATIC NET
S7-300 - Industrial Ethernet /
PROFINET
CP 343-1 Lean
Manual
Manual Part B
10/2012
C79000−G8976−C198−07
Preface
Properties / services
1
Performance data
2
Requirements for use
3
LEDs
4
Installation, connecting up
and commissioning
5
Notes on configuration and
operation
6
Service and maintenance
7
Technical specifications
8
Approvals
A
References
B
Vue de la page 0
1 2 3 4 5 6 ... 67 68

Résumé du contenu

Page 1 - C79000−G8976−C198−07

CP 343-1 Lean ____________________________________________________________________________________________________________________________________

Page 2

Properties / services 1.3 Communication services CP 343-1 Lean 10 Manual, 10/2012, C79000−G8976−C198−07 ● New program block FB10 AG_CNTEX for co

Page 3 - Preface

Properties / services 1.4 Other services CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 11 ● S7 communication and PG/OP communication with t

Page 4

Properties / services 1.4 Other services CP 343-1 Lean 12 Manual, 10/2012, C79000−G8976−C198−07 or – NTP mode (NTP: Network Time Protocol) The C

Page 5 - FAQs on the Internet

Properties / services 1.5 The CP as Web server CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 13 1.5 The CP as Web server Enabling the Web s

Page 6 - Security messages

Properties / services 1.5 The CP as Web server CP 343-1 Lean 14 Manual, 10/2012, C79000−G8976−C198−07

Page 7 - Table of contents

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 15 Performance data 22.1 Transmission and reaction times Measured values on the Internet Note

Page 8

Performance data 2.3 Characteristics of S7 communication CP 343-1 Lean 16 Manual, 10/2012, C79000−G8976−C198−07 ● Further TCP connections for We

Page 9

Performance data 2.4 Characteristic data of the SEND/RECEIVE Interface CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 17 Table 2- 3 Characte

Page 10 - 1.3 Communication services

Performance data 2.5 PROFINET IO characteristic data CP 343-1 Lean 18 Manual, 10/2012, C79000−G8976−C198−07 2.5 PROFINET IO characteristic data

Page 11 - 1.4 Other services

Performance data 2.6 Characteristic data of the integrated switch CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 19 Execution times of the FC

Page 12 - 1.4 Other services

Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY Order number: C79000−G8976−C198 Ⓟ 10/2012 Technical data subject to change Copyrig

Page 13 - 1.5 The CP as Web server

Performance data 2.6 Characteristic data of the integrated switch CP 343-1 Lean 20 Manual, 10/2012, C79000−G8976−C198−07

Page 14 - 1.5 The CP as Web server

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 21 Requirements for use 33.1 Operation in control device families The CP can be operated in the

Page 15 - Performance data

Requirements for use 3.1 Operation in control device families CP 343-1 Lean 22 Manual, 10/2012, C79000−G8976−C198−07 CPU Order number CPU 314 IF

Page 16 - Number of connections

Requirements for use 3.2 Project engineering CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 23 Table 3- 2 Use of the CP with C7 control syst

Page 17 - Performance data

Requirements for use 3.3 Programming CP 343-1 Lean 24 Manual, 10/2012, C79000−G8976−C198−07 Installatio of the support package ● STEP 7 V5.5 Ins

Page 18 - Size of the user data

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 25 LEDs 4 LEDs The display on the front panel consists of the following LEDs that indicate the op

Page 19

LEDs CP 343-1 Lean 26 Manual, 10/2012, C79000−G8976−C198−07 LEDs for displaying the operating mode The different combinations of the LEDs on th

Page 20

LEDs CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 27 The "MAINT" LED Note When the "MAINT" LED lights up, important e

Page 21 - Requirements for use

LEDs CP 343-1 Lean 28 Manual, 10/2012, C79000−G8976−C198−07

Page 22

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 29 Installation, connecting up and commissioning 55.1 Important notes on using the device Safety

Page 23 - 3.2 Project engineering

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 3 Preface  Legend: ① LEDs ② Under the front panel: PROFINET interface, 2 x 8-pin RJ-45 ja

Page 24 - 3.3 Programming

Installation, connecting up and commissioning 5.1 Important notes on using the device CP 343-1 Lean 30 Manual, 10/2012, C79000−G8976−C198−07 WARN

Page 25 - CP 343-1 Lean

Installation, connecting up and commissioning 5.2 Installing the CP, connecting power and ground CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−

Page 26 - CP 343-1 Lean

Installation, connecting up and commissioning 5.2 Installing the CP, connecting power and ground CP 343-1 Lean 32 Manual, 10/2012, C79000−G8976−C

Page 27 - The "MAINT" LED

Installation, connecting up and commissioning 5.2 Installing the CP, connecting power and ground CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−

Page 28

Installation, connecting up and commissioning 5.3 Connecting the CP to Ethernet CP 343-1 Lean 34 Manual, 10/2012, C79000−G8976−C198−07 The PG / P

Page 29 - General notices

Installation, connecting up and commissioning 5.3 Connecting the CP to Ethernet CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 35 ,QWHJUDWHG

Page 30

Installation, connecting up and commissioning 5.3 Connecting the CP to Ethernet CP 343-1 Lean 36 Manual, 10/2012, C79000−G8976−C198−07

Page 31

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 37 Notes on configuration and operation 6 NOTICE The front panel must be kept closed during ope

Page 32 - Legend:

Notes on configuration and operation 6.3 Network settings CP 343-1 Lean 38 Manual, 10/2012, C79000−G8976−C198−07 Module access protection The con

Page 33 - Downloading and addressing

Notes on configuration and operation 6.3 Network settings CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 39 ● In STEP 7 special diagnostics

Page 34 - Diagnostics

Preface CP 343-1 Lean 4 Manual, 10/2012, C79000−G8976−C198−07 Note Names  In this document, the term "CP" is used instead of the

Page 35 - 6ZLWFK 6ZLWFK

Notes on configuration and operation 6.4 Influence of MPI on connections via Industrial Ethernet CP 343-1 Lean 40 Manual, 10/2012, C79000−G8976−C

Page 36

Notes on configuration and operation 6.6 Effects of multicast communication on RT communication CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−0

Page 37 - 6.2 Controlling the mode

Notes on configuration and operation 6.8 Media redundancy CP 343-1 Lean 42 Manual, 10/2012, C79000−G8976−C198−07 6.7.2 Obtain IP address vie DHC

Page 38 - 6.3 Network settings

Notes on configuration and operation 6.10 SNMP agent CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 43 The information on the properties of S

Page 39 - Further notes:

Notes on configuration and operation 6.10 SNMP agent CP 343-1 Lean 44 Manual, 10/2012, C79000−G8976−C198−07 ● Write access is permitted only for

Page 40 - Sporadically used services

Notes on configuration and operation 6.11 Possible security gaps on standard IT interfaces: preventing unauthorized access CP 343-1 Lean Manual, 1

Page 41 - 6.7 IP configuration

Notes on configuration and operation 6.13 Permitted length of ICMP packets CP 343-1 Lean 46 Manual, 10/2012, C79000−G8976−C198−07 6.12.2 Program

Page 42 - 6.10 SNMP agent

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 47 Service and maintenance 77.1 Memory reset / reset to factory defaults If the CP was configure

Page 43 - Supported MIBs

Service and maintenance 7.2 Loading new firmware CP 343-1 Lean 48 Manual, 10/2012, C79000−G8976−C198−07 ● Reset to factory settings – In STEP 7

Page 44 - 6.10 SNMP agent

Service and maintenance 7.3 Replacing a module CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 49 If the loading with the firmware loader is i

Page 45

Preface CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 5 Current manual release on the Internet You will also find the current version of thi

Page 46

Service and maintenance 7.3 Replacing a module CP 343-1 Lean 50 Manual, 10/2012, C79000−G8976−C198−07 7.3.2 module replacement / upgrading Repla

Page 47 - Service and maintenance

Service and maintenance 7.3 Replacing a module CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 51 Module replacement Please follow the procedu

Page 48 - 7.2 Loading new firmware

Service and maintenance 7.3 Replacing a module CP 343-1 Lean 52 Manual, 10/2012, C79000−G8976−C198−07 Module replacement: Special feature of IP a

Page 49 - 7.3 Replacing a module

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 53 Technical specifications 8 Table 8- 1 Technical specifications Technical specifications Attac

Page 50 - Upgrading

Technical specifications CP 343-1 Lean 54 Manual, 10/2012, C79000−G8976−C198−07 For further data, refer to section Performance data (Page 15)

Page 51 - Module replacement

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 55 Approvals A Approvals issued Note Issued approvals on the type plate of the device The speci

Page 52 - 7.3 Replacing a module

Approvals CP 343-1 Lean 56 Manual, 10/2012, C79000−G8976−C198−07 ● EC directive 94/9/EC "Equipment and protective systems intended for us

Page 53 - Technical specifications

Approvals CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 57 cULus HAZ.LOC. approval Underwriters Laboratories Inc. cULus Listed 7RA9 IND. CON

Page 54

Approvals CP 343-1 Lean 58 Manual, 10/2012, C79000−G8976−C198−07

Page 55 - Approvals

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 59 References B Finding the SIMATIC NET documentation ● Catalogs You will find the order numbers

Page 56 - ATEX approval

Preface CP 343-1 Lean 6 Manual, 10/2012, C79000−G8976−C198−07 Security messages Note For its automation and drives product portfolio, Siemens

Page 57 - Notice for Korea (KCC)

References B.1 On configuring, commissioning and using the CP CP 343-1 Lean 60 Manual, 10/2012, C79000−G8976−C198−07 B.1 On configuring, commiss

Page 58

References B.3 On programming CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 61 /5/ SIMATIC Configuring Hardware and Connections with STEP 7

Page 59 - References

References B.4 On installing and commissioning the CP CP 343-1 Lean 62 Manual, 10/2012, C79000−G8976−C198−07 /9/ SIMATIC NET Industrial Communica

Page 60

References B.5 For application and configuration of PROFINET IO CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 63 Siemens AG and SIMATIC S7

Page 61 - B.3 On programming

References B.7 On setting up and operating an Industrial Ethernet network CP 343-1 Lean 64 Manual, 10/2012, C79000−G8976−C198−07 B.7 On setting

Page 62

References B.9 Other topics CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 65 /20/ RFC 1006 (ISO Transport Service on top of the TCP Version:

Page 63 - B.6 On IT security

References B.9 Other topics CP 343-1 Lean 66 Manual, 10/2012, C79000−G8976−C198−07

Page 64 - B.9 Other topics

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 67 Index A Abbreviation "CX", Addressing, 33 ATEX, 30 C Cabinet, 30 Cables for tempe

Page 65 - B.9 Other topics

Index CP 343-1 Lean 68 Manual, 10/2012, C79000−G8976−C198−07

Page 66 - B.9 Other topics

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 7 Table of contents Preface ...

Page 67

Table of contents CP 343-1 Lean 8 Manual, 10/2012, C79000−G8976−C198−07 6.7.1 Detection of double IP addressing in the network ...

Page 68

CP 343-1 Lean Manual, 10/2012, C79000−G8976−C198−07 9 Properties / services 11.1 Application The CP 343- Lean communications processor is intended f

Commentaires sur ces manuels