FireFinder XLS Components (cont.’d)
RNI Remote Network Interface
RNI Remote Network Interface
The Remote Network Interface (Model RNI) provides a
connection point for use with equipment mounted in a
remote-lobby enclosure on the FireFinder XLS FACP.
Model RNI is used to provide additional input, output and
control features to the system remotely, via the main
control panel. These additional features may include control
switches and indicators: (Models SCM-8, LCM-8 and
FCM-6), remote-emergency paging microphones or
telephones: (Models LVM, FMT), or controls used in
graphic annunciators (Models SIM16, OCM-16) or system-
status display with the ability to acknowledge alarms,
silence audibles and reset the system (Model SSD-C-
REM). Model RNI allows Model PMI to be mounted in the
Model REMBOX2 or Model REMBOX4 remote lobby
enclosure.
RPM Remote Printer Module
RPM Remote Printer Module
The Remote Printer Module (Model RPM) provides a means
of connecting the FireFinder XLS system to a printer,
such as Model PAL-1, for creating a hard copy of system
status and configuration reports. Simultaneously, Model
RPM provides an output port that can be configured to
communicate with external systems.
System-Status Display
SSD-Series System-Status Display
The System Status Display (SSD-series model displays) is
a remote LED / LCD display that shows the local status of a
FireFinder XLS system. An LED illuminates when Alarm,
Supervisory, Trouble, and Security events occur on the
system. A (4) four-line liquid-crystal display (LCD) will
give details of the event in alphanumeric form.
The display can be toggled to display additional events.
Optional remote system control capabilities are available.
Models SSD-C, SSD-C-INT, and Model SSD-C-REM have three
(3) additional control buttons to acknowledge events,
silence audible circuits, and reset the system.
Models SSD-C and SSD-C-INT have an integral keyswitch
that enables these control buttons to operate.
Model SSD-C-REM is located within a locked cabinet.
Hence, no additional keyswitch is required for enabling
the control buttons.
CAB1 Single Row Enclosure
CAB1 Single Row Enclosure
Model CAB 1, the smallest of the FireFinder XLS
enclosures, can house a single Model CAB-MP cabinet
mounting plate for mounting card cages, power supplies
and bulk amplifiers. Model CAB1 also has four (4)
mounting slots on the inner door for mounting Model PM
I
and Model
ID-MP switch module brackets.
Model CAB1 comes complete with a black back box; black
inner and outer doors; a single lock and key set on the outer
door; a single, installed cabinet mounting plate (Model
CAB-MP), and a single, installed outer door lens plate
(Model OD-LP). A red version (Model CAB1-R) is also
available – approximate size: 27" (68.6cm.) high, 26"
(66cm.) wide, and 8" (20.3cm.) deep.
MDACT - Multi-Point Digital Alarm
Communicator Transmitter
MDACT - Multi-Point Digital Alarm Communicator
Transmitter
The Multi-Point Digital Alarm Communicator Transmitter
(Model MDACT) is used in FireFinder XLS systems where
point identification of Alarm, Supervisory, Security and
Trouble events is required at Central or Remote Receiving
Stations. An intelligent RS-485 communications protocol
transmits all system information to Model MDACT.
The installer selects the specific event or groups of
events that are set to transmit from Model MDACT over
phone lines to listed receiving station equipment. In
turn, Model MDACT can transmit point information, via the
Ademco Contact ID and the SIA protocol. A Mounting Plate
(Model MOM2-XMP), MOM-2 card cage, and an XMI
Interface Card are required for installation.