Appendix E: Device Data Format
102 Siemens Energy & Automation, Inc.
Trip by Breaker Failure
Protection
59 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L1 only
60 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L1E 61 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L2 only
62 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L2E 63 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L12
64 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L12E 65 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L3 only
66 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L3E 67 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L13
68 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L13E 69 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L23
70 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L23E 71 ms since fault (-1 = no occurance)
Emerg. O/C fault detection
L123
72 ms since fault (-1 = no occurance)
Emerg. O/C fault detection L123E 73 ms since fault (-1 = no occurance)
Emerg. O/C protection:
General Trip
74 ms since fault (-1 = no occurance)
AR: Close command from
auto-reclose
75 ms since fault (-1 = no occurance)
AR: Definitive Trip 76 ms since fault (-1 = no occurance)
Dist.: Fault detection only phase L1 77 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,E 78 ms since fault (-1 = no occurance)
Dist.: Fault detection only phase L2 79 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L2,E 80 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,2 81 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,2,E 82 ms since fault (-1 = no occurance)
Dist.: Fault detection only phase L3 83 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L3,E 84 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,3 85 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,3,E 86 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L2,3 87 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L2,3,E 88 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,2,3 89 ms since fault (-1 = no occurance)
Dist.: Fault detection phase L1,2,3,E 90 ms since fault (-1 = no occurance)
Dist.: Fault det. In forward direction 91 ms since fault (-1 = no occurance)
Dist.: Fault det. In reverse
direction
92 ms since fault (-1 = no occurance)
Dist.: Time T1 (Zone Z1) expired 93 ms since fault (-1 = no occurance)
Dist.: Time T2 (Zone Z2) expired 94 ms since fault (-1 = no occurance)
Real-Time Device Data Stored in PLC (7SA513) (Continued)
Function Register Location in
PLC Block
1
Range or Contents