Vue de la page 51
Overview of the DP Base Interface
DP Base Programming Interface for CP 5613/CP 5614
52
C79000-G8976-C108-01
Receiving and Responding to a DPC1 Alarm
Step Action Meaning
1
Attempt to receive alarm
(DP_read_alarm)
If there is no alarm, this is indicated by
the function result.
2
If received: Send alarm
acknowledgment
(DP_alarm_ack)
On completion of the function, the job
is active.
3 Poll final result
(DP_get_result) until the
job is completed
The result can be recognized by the
order_id in the request field.