Description of the DP Functions, Data, and Error Codes
DP Base Programming Interface for CP 5613/CP 5614
C79000-G8976-C108-01
141
Data Structure (for data_blk parameter)
Indication Content of the data_blk Data Structure
DPS_CHK_PRM DPR_WORD status
Value Meaning
DPS_PRM_OK Parameter assignment data accepted.
DPS_PRM_FAULT Parameter assignment not accepted, the
slave does not enter data exchange.
DPS_CHK_CFG DPR_WORD status formatting
Value Meaning
DPS_CFG_OK Configuration data accepted.
DPS_CFG_FAULT Configuration not accepted, slave does
not enter data exchange.
DPS_NEW_SSA
DPR_WORD status formatting
Value Meaning
DPS_SSA_OK Set slave address completed.
Return Value
Name Description
DP_OK Successful completion of the function
other Unsuccessful completion of the function