Siemens SIMATIC NET PROFIBUS Manuel de service Page 126

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 238
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 125
Description of the DP Functions, Data, and Error Codes
DP Base Programming Interface for CP 5613/CP 5614
126
C79000-G8976-C108-01
4.2.5 DPS_stop
Purpose
This function is used to deactivate the slave module. The slave module then no
longer reacts on the bus.
Syntax
DPR_DWORD DPS_stop (DPR_DWORD user_handle, // in
DP_ERROR_T *error ); // out
Parameters
Name Description
user_handle User handle assigned with the DPS_open call.
error
Address of a structure provided by the user program of the
type DP_ERROR_T. If an error occurred, the structure
contains details for troubleshooting (see Section 4.4).
Return Value
Name Description
DP_OK Successful completion of the function
other Unsuccessful completion of the function