Vue de la page 156
SIMATIC S7-400
Modules for SIMATIC S7-400F/FH
SIPLUS isolation modules
6/157
Siemens ST 70 · 2013
6
Overview
Permits combined operation of fail-safe signal modules in
safety mode and standard S7-300 modules in the same
ET 200M system.
The isolation module is not required if the safety class SIL 3 or
safety category < Cat. 4 is to be achieved.
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific infor-
mation was added.
For technical documentation on SIPLUS, see:
www.siemens.com/siplus-extreme
Ordering data
Order No.
SIPLUS S7-300 isolation module
Order No. 6AG1 195-7KF00-2XA0
Order No. based on 6ES7 195-7KF00-0XA0
Ambient temperature range
- 25 ... +60 °C
Conformal coating Coating of the printed circuit boards
and the electronic components
Technical data
The technical data of the standard
product applies except for the ambi-
ent conditions.
Compliant with the standards for
electronic equipment used on rolling
stock (EN 50155, temperature T1,
category 1)
Yes
Ambient conditions
Relative humidity 100%, condensation/frost permissi-
ble. No commissioning if condensa-
tion present.
SIPLUS isolation module 6AG1 195-7KF00-2XA0
(extended temperature range and
medial exposure)
for simultaneous operation of
fail-safe and standard modules
in the same ET 200M
Accessories
SIPLUS ET 200M
isolation bus module F
6AG1 195-7HG00-2XA0