Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 9
See appendices to Chapters 7.10, 7.11, and 7.12.
This PN station name can also be used as a device name.
The device name is displayed in the parameter tree in SOPAS ET and helps when searching for devices.
If the CLV61x Dual Port is not yet active in the PROFINET data exchange to the IO Controller (PLC), the
PNIP Address, PN Subnet Mask and the PN Standard Gateway of the CDF61x Dual Port can also be set
here.
However, note that this is normally carried out automatically by the IO controller (PLC) if the PN station
name matches. If the IP is automatically assigned by the IO controller (PLC), the IP address is “temporarily
accepted and then displayed as not remanent in SOPAS ET.
Remanent: (IP address)
This indicates whether the PN IP address, subnet and gateway are permanently stored and also
immediately available once power is restored or whether these have only been temporarily assigned and
the IP address is 0.0.0.0 following a restart. This characteristic is obligatory for PROFINET IO.
Remanent: (PN station name):
This indicates whether the station name has been permanently stored.
PN status:
connected Der CLV61x Dual Port is exchanging data with PROFINET.
This corresponds to the "BF" LED = off.
After changing the PN name and possibly the IP address, click "Apply" to use the new settings.
In addition, the Communications Mode can be set here. If changed from the default setting, the
parameters must be saved permanently and the CLV61x Dual Port restarted. For details about the
communications modes, see Chapter 5
Likewise, the IM data, such as Plant designation, Location designation, Installation date (mandatory format
yyyy-mm-dd hh:mm) and Additional information, can also be displayed and set here. This data is only
used for organization and can be read and written by the IO controller (PLC) or by the higher-level system.
The required output format must also be set. The output format given to PROFINET must not include any
STX/ETX frame, because transport works without this ID. If STX/ETX is set as the frame, the characters are
entered in the data for the PLC as control characters, which is not normally desirable.