Additional Information CLV61x Dual Port (PROFINET IO)
8017978 / 2014-11-20 © SICK AG · Germany · All rights reserved · Subject to change without notice 32
6.1.1 Ctrl bits In
By adding the Ctrl bits In, the PLC can monitor the digital inputs and outputs of the CLV61x Dual Port.
Here is the assignment for the CLV61x Dual Port.
Add. Bit Name Meaning
Add.+1
D0
Device Ready
Status of the CLV61x Dual Port
Add.+1
D1
Reserved
Add.+1
D2
Good Read *
Status of the last read results *
Add.+1
D3
No Read *
Status of the last read results *
Add.+1
D4
External Output 1
Only available as a bit logical, no hardware output
Add.+1
D5
External output 2
Only available as a bit logical, no hardware output
Add.+1
D6
Result 1
Only available as a bit logical, no hardware output
Add.+1
D7
Result 2
Only available as a bit logical, no hardware output
Add.
D8
-
Reserved
Add.
D9
-
Reserved
Add.
D10
Sensor 1
Status of dig. input sensor 1.
(Hardware dependent, equipment type on request)
Add.
D11
-
Reserved
Add.
D12
Reserved
Add.
D13
Reserved
Add.
D14
Reserved
Add.
D15
Toggle
Inverted after each read cycle.
Observe byte order: D0 stands for the least significant bit of Add.+1.
* The bits are valid if the "Toggle" bit changes.