Connecting up
6.8 Inserting / removing the C-PLUG
SCALANCE W786 outdoor access point
Operating Instructions, 06/2013, A5E02280428-08
53
6.8
Inserting / removing the C-PLUG
WARNING
Danger from line voltage
Once you have removed the housing cover, there is the danger from line voltage in the
area of the connecting terminals on the power supply adapter.
Only authorized personnel is permitted to open the device and carry out any work on the
open device (e.g. connection and disconnection of lines, operating the reset button,
replacing the C-PLUG).
NOTICE
A C-PLUG may only be inserted or removed when the device is turned off.
Inserting the C-PLUG
Figure 6-9 Location of the C-PLUG with the housing cover removed
Follow the steps below to insert a C-PLUG in the device:
1. Turn off the power to the device.
2. Remove the housing cover, see section "Removing/fitting the housing cover".
3. Remove the C-PLUG from the slot. The housing of the C-PLUG has a protruding ridge on
the long side. The C-PLUG can only be inserted when this ridge is at the top right. The
slot in the SCALANCE W786 has a corresponding groove at this position. Make sure that
the C-PLUG is inserted completely into the slot.
4. Screw the housing cover back onto the device.