Siemens EK 746 Series Instructions d'exploitation Page 51

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 90
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 50
Connecting up
6.6 Connection for Industrial Ethernet
SCALANCE W786 outdoor access point
Operating Instructions, 06/2013, A5E02280428-08
51
6.6
Connection for Industrial Ethernet
Device variants
With a SCALANCE W786, you have the choice of two Ethernet ports:
RJ-45 jack
ST duplex socket for multimode FO cables 1310 nm and a maximum cable length of 3000
m
Procedure for connecting an Ethernet cable
Figure 6-7 Position of the Ethernet port with the housing cover removed
Perform the following steps to connect an Ethernet cable to a
SCALANCE W786:
1. Insert the connector of the Ethernet cable in the corresponding socket of the SCALANCE
W786. If you use FO cables, make sure that the transmit and receive lines are correctly
connected. The location of the socket for RX and TX is shown in the figure above.
2. Secure the Ethernet cable with a strain relief clamp. For more detailed information on this
topic, refer to the section "Connecting the cables".
Vue de la page 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 89 90

Commentaires sur ces manuels

Pas de commentaire