Siemens MC55 Manuel d'utilisateur Page 44

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 469
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 43
MC55 AT Command Set
2.9 AT^SMSO
s
m
obil
e
MC55_ATC_V01.05 Page 44 of 469 2/10/04
Confidential / Released
2.9 AT^SMSO Switch off mobile station
Syntax
Unsolicited Result Code
^SHUTDOWN
Indicates that the power-off procedure is finished and the module will be switched off within 1 second
Command Description
The exec command initiates the power-off procedure. Low level of the module's VDD pin and display of URC
"
^SHUTDOWN" verifies that the procedure has completed and the module has entered the POWER DOWN mode.
Therefore, be sure not to disconnect the operating voltage until VDD is low or until URC "
^SHUTDOWN" is dis-
played . Otherwise, you run the risk of losing data. For further details on how to turn off the module see the [2].
Notes
Do not send any command after this command.
If AT^SMSO is entered on one of the Multiplexer channels the ME closes the Multiplexer channels, terminates
the Multiplexer and deactivates all other functions. Then, the URC "
^SHUTDOWN" will be issued on the phys-
ical serial interface (ASC0). The URC will be transmitted at the bit rate last activated on ASC0 for use with
the Multiplex driver.
If both interfaces ASC0 and ASC1 are connected the URC appears on both of them.
Test Command
AT^SMSO=?
Response(s)
OK
Exec Command
AT^SMSO
Response(s)
^SMSO: MS OFF
OK
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
SIEMENS
Vue de la page 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 468 469