The AT Commands described in this chapter are related to various areas.
18.1 A/ Repeat previous command line
Syntax
Command Description
Repeat previous command line.
Notes
Line does not need to end with terminating character.
After beginning with the character "a" or "A" a second character "t", "T" or "/" has to follow. In case of using a
wrong second character, it is necessary to start again with character "a" or "A".
If autobauding is active, the command
A/ cannot be used (see AT+IPR).
Exec Command
A/
Response(s)
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
V.25ter