MC55 AT Command Set
16.17 AT^SNFV
s
m
obil
e
MC55_ATC_V01.05 Page 419 of 469 2/10/04
Confidential / Released
16.17 AT^SNFV Set loudspeaker volume
Syntax
Command Description
The test command returns the supported values of the parameter <outStep>.
The read command returns the current value of parameter
<outStep>.
The write command can be used to set the volume of the loudspeaker to the value
<outCalibrate> addressed
by
<outStep>.
Parameter Description
The actual volume of each step is defined by the parameter <outCalibrate>, which can be set with AT^SNFO.
0...4
(P)
Test Command
AT^SNFV=?
Response(s)
^SNFV: (list of supported <outStep>s)
OK
Read Command
AT^SNFV?
Response(s)
^SNFV: <outStep>
OK
Write Command
AT^SNFV=<outStep>
Response(s)
OK
ERROR
+CME ERROR
PIN ASC0 ASC1 MUX1 MUX2 MUX3
! % % % % %
Reference(s)
SIEMENS
<outStep>
(num)