MC55 AT Command Set
15.7 AT^SPBG
s
m
obil
e
MC55_ATC_V01.05 Page 384 of 469 2/10/04
Confidential / Released
Command Description
The test command returns the index range for this command, the maximum length of <number> field, and the
maximum length of
<text> field.
Note: The length may not be available while SIM storage is selected. If storage does not offer format information,
the format list should be empty parenthesises.
The write command selects the index of the phonebook entry, that is to be displayed, in the sorted list of phone-
book, or the range of indices to display.
If no
<index2> is given, only the entry at <index1> will be displayed.
If parameter
<RealLocReq>=1, the actual location of the entry displayed will be indicated in parameter <loca-
tion>
. If <RealLocReq> is omitted or <RealLocReq>=0, parameter <location> will not be displayed.
The indices displayed in the first parameter of the write command response are indices in the sorted list of
entries, and not related to the entries' location in the phonebook. They may not be used for other phonebook
commands or
ATD><mem><n>. Instead, parameter <location> must be used for these purposes.
Parameter Description
The first index number within the sorted list of phonebook for which the corresponding entry is to be displayed.
The supported range is given in the test command response.
If <index 1> exceeds the upper bound
<used>, the AT command will return a CME ERROR 21.
The last index number within the sorted list of phonebook for which the corresponding entry is to be displayed.
The supported range is given in the test command response.
If both
<index1> and <index2> are in the range indicated by the test command in parameter <used>, the list
of entries will be output and terminated with OK.
If
<index2> exceeds the range indicated by the test command in parameter <used>, the list of entries will be
output but terminated with a +CME ERROR 21 "INVALID INDEX".
Is a display of the "real" <location> of the entry required?
[0] Do not display an entry's "real" location number. Parameter
<location> will
not be displayed.
1 Display the "real" location number as parameter
<location> at the end of the
entry.
String type phone number in format specified by
<type>.
The number parameter may be an empty string.
type of address octet
145 dialling string
<number> includes international access code character '+'
209 dialling string
<number> contains printable non-alphabetic non-digit charac-
ters saved with the number string.
For further detail, check the parameter descriptions for at command
AT+CPBW.
129 otherwise
<index1>
(num)
<index2>
(num)
<RealLocReq>
(num)
<number>
(str)
<type>
(num)