MC55 AT Command Set
15.2 AT+CPBR
s
m
obil
e
MC55_ATC_V01.05 Page 371 of 469 2/10/04
Confidential / Released
15.2 AT+CPBR Read from Phonebook
This command serves to read one or more entries from the phonebook selected with AT command AT+CPBS.
It can be used only after the phonebook's data has been read from the SIM successfully. Reading starts after
successful SIM authentication has been performed and may take up to 30 seconds depending on the SIM used.
While this read process is in progress, an attempt to use any of the phonebook commands will result in "+CME
Error: SIM busy".
Syntax
Command Description
The test command returns the location range supported by the current phonebook storage, the maximum length
of
<number> field and the maximum length of <text> field. Note: Length information may not be available while
SIM storage is selected. If storage does not offer format information, the format list contains empty parenthe-
sizes.
The write command determines the phonebook entry to be displayed with
<location1> or a location range
from
<location1> to <location2>. Hence, if no <location2> is given only the entry at <location1> will
be displayed.
If no entries are found at the selected location "OK" will be returned.
Test Command
AT+CPBR=?
Response(s)
+CPBR: (1-<maxloc>), <nlength>, <tlength>
OK
+CME ERROR
Write Command
AT+CPBR=<location1>[, <location2>]
Response(s)
[+CPBR: <location1>, <number>, <type>, <text> ]
[+CPBR: <location2>, <number>, <type>, <text> ]
OK
+CME ERROR
PIN ASC0 ASC1 MUX1 MUX2 MUX3
% % % % % %
Reference(s)
GSM 07.07, GSM 11.11