5.2 Power on Machine
5.2.1 Cable Connection
1) Make sure theEMERGENCY
STOPswitch is in OFF position..
2) Connect cable to the main power
terminal port in the cabinet and
make sure to screw it tight.
3) Make sure once again the matching
voltage and phase are the same with
machine specification.
4) Please connect ground wire to PE
terminal in terminal seat, ground
resistance should be less than 100.
Any question concerning grounding,
please contact local Leadwell agent.
5) To prevent dust entering into
cabinet, please use water proof plug
or seal with silicon glue.
6) Please install device to detect
electrical leakage.
Specifications30mA
7) Output cable connect
specification:14mm